August 12, 2026

BEM-1

Our first family of biomedical models: two that read biomedical writing, and two that write it.

Biomedical Epistemic ModelExamine · Examine Mini · Compose · Critique

Where BEM began.

BEM-1, the Biomedical Epistemic Model, was our first family of biomedical models: two that read biomedical writing and two that write it. BEM-1 Examine classifies a text’s evidence tier with a calibrated confidence and scores its hedging and claim strength; Examine Mini screens every input first and passes the hardest 1% up, matching Examine’s accuracy end to end at 2.86 times the speed on CPU. Compose writes under a requested study design, and Critique raises the methodological objections a careful reviewer would ask first. On held-out abstracts, Examine reaches 94.76% evidence-tier accuracy. Two findings shaped what came next: hedged writing turned out not to signal weak evidence, and Compose’s study-design conditioning was a null. BEM-2 rebuilt the writer, and blind judges now recognise the requested design in 55% of its texts, against 23% for BEM-1 Compose.

evidence-tier accuracy for Examine, on held-out abstracts
94.76%
macro-F1 for Examine Mini on 31,527 abstracts it never saw in any form
92.00%
of inputs Examine Mini settles alone in the cascade, at 95.09% accuracy
99.0%
faster on CPU than Examine alone, with no loss of accuracy
2.86×

The family.

BEM-1 Examine

Reads

Classifies a text’s evidence tier with a calibrated confidence, and scores its hedging and claim strength.

BEM-1 Examine Mini

Reads

A compact version of Examine that screens every input first and passes the hardest 1% up.

BEM-1 Compose

Writes

A small biomedical chat model that writes under a requested study design.

BEM-1 Critique

Writes

Raises the methodological objections a careful reviewer would ask of a claim or abstract first.

Results.

Measured by Essarion, including where BEM-1 fell short.

Examine Mini

Evidence tier, by study design

F1 for Examine Mini on held-out abstracts, in their natural mix of study designs.

84.9
Meta-analysis
91.9
Randomized trial
96.5
Observational
97.2
Preclinical
96.2
Case report
92.3
Review
Examine MiniExamine

The cascade

Seconds to tier 200 abstracts on CPU. Accuracy end to end is 94.69%, against 94.66% for Examine alone. Lower is better.

Mini first, the hardest 1% to Examine
2.99 s
Examine alone
8.57 s
ExamineExamine Mini

Mini keeps up with Examine

Evidence-tier accuracy on the same held-out abstracts, in their natural mix and balanced across designs.

ExamineExamine Mini
94.76%
Examine
94.64%
Examine Mini
Natural mix
95.34%
Examine
95.24%
Examine Mini
Balanced
Examine

Overclaim detection, on real text

ROC-AUC for Examine. The first set is 68% rule-based synthetic text, so it flatters; on real writing the score drops.

0.92
Mostly synthetic set
0.89
Lay summaries
0.75
Title drift
Compose

Writing for a requested design: a null

How often Examine recovers the study design Compose was asked to write in, over 600 generations, against the chance floor.

27.0%
BEM-1 Compose
16.7%
Chance

One finding worth knowing: hedged writing does not mean weak evidence.

We tested whether more hedging comes from lower tiers of evidence, three ways, on about 430,000 held-out abstracts. None of the correlations was significant. Case reports are among the least hedged, because they narrate one patient and make no general claim; meta-analyses are among the most, because they discuss heterogeneity and bias.

The models are private.

BEM-1 is succeeded by BEM-2, available in Essarion Science.

Ask harder questions.

If you are working on similar problems, we would like to hear from you.